Pressure Gauges

Electrical Contact

MICRO pressure gauges with electrical contacts, these incorporate a mechanical magnetic snap action contact mechanism in to an analogue pressure indicator. They generate ON and OFF electrical signals at preset value of measurement. These signals can be used to activate or deactivate buzzer, alarm, pilot lamp, control motor, pump, valve or any other process which requires controlling. These eliminate the need of separate switches for such controlling of equipments. Point of actuation is adjustable between 10% to 90% of FS.

(Confirming to EN-837-1 or 3 & IS-3624)

Nominal size

Ø 100 & 150 mm

Accuracy

Gauge: ±1% of FS
Switching: ±2% of FS
Case & Bezel SS 304 case with Snap Action bayonet
lock type bezel (SS 316 Optional)
Ingress Protection IP 65 as per EN 60 529 or IS/IEC 60 529
IP 68 as per IS/IEC 60 529 – Optional
Pressure element — Bourdon Tube SS 316 / SS 316L / SS 316Ti (Monel 400 Optional)
(< 100 bar ’C’ shape / ≥ 100 bar helical shape)
Over pressure limit ≤ 100 bar - 125% of FS
> 100 bar < 600 bar - 115% of FS
> 600 bar < 1600 bar - 110% of FS
Movement SS 304 (SS 316 optional)
Socket SS 304 / SS 316 / SS 316L (Monel 400 Optional)
Dial Aluminium —Pre-coated White with black marking
Pointer Aluminium —Black Finish Center zero / Micro Zero Adjustment
Window Extended Clear Poly Carbonate Hood / Transparent Acrylic
Joints Argon welded
Sealing gasket Neoprene Rubber (EPDM Optional)
Blow out protection Neoprene Rubber (EPDM Optional) On Back of Case
Pressure relief Top of Case with Vent Valve (On Request)
Process Connection 1/4” / 3/8” / 1/2” BSP / NPT / BSPT (Male)
M20 X 1.5 (Male), Other Male or Female Connection
On Request
Permissible temperature Ambient : -25'C to 65'C
Process : Maximum 1000C
Type of mounting Bottom Connection Direct Mounting
Back Connection Direct Mounting
Bottom Connection Surface Mounting
Back Connection Panel Mounting
Back Connection Bracket Mounting
Pressure range -30” Hg … 0 … 2500 bar
Contact Type —(Internal / External) Magnetic Snap Action with Silver Nickel Alloy
Contact Standard (Palladium Contact Optional)
No. of Contact & Configuration Single ( 1NO, 1NC) / Double (1NO+NC, 1NC+NO,
2NO, 2NC)
Contact Rating 380 V AC/DC, 50 VA, 1 Amp (Standard) /
Max. 5 Amp (Optional)
Contact Set Point Between 10 to 90 % of FS
Optional Available features Customized Scale with different Unit of Measurement or logo
Electrical Contact gauge attached with Diaphragm Seal
Electrical Contact with Differential Pressure Gauge
Electrical Contact with Schaffer or Low Pressure Diaphragm Operated Gauge
Triple / Quadruple Contact
Inductive Contact, Potential Free Contact
Coming soon...